Diagnostic Value of Magnetic Resonance Imaging in Detecting Meniscus Injuries Keeping Arthroscopy as Gold Standard
DOI:
https://doi.org/10.51985/Keywords:
Knee injuries; Magnetic resonance imaging; Meniscus; Arthroscopy; Sensitivity and specificityAbstract
Objective: To determine the diagnostic accuracy of magnetic resonance imaging (MRI) for detecting meniscal injuries in patients with knee trauma, using arthroscopy as the reference standard.
Study design and setting: Cross-sectional validation study conducted in the Department of Radiology, PAEC General Hospital, Islamabad.
Methodology: Using non-probability consecutive sampling, 143 patients aged 18–70 years with clinically suspected meniscal injury after knee trauma within the preceding two months were enrolled. All participants underwent knee MRI on a 1.5-T scanner with a dedicated knee coil, followed by arthroscopy. MRI findings were compared with arthroscopic findings, and a 2×2 contingency table was used to calculate sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and diagnostic accuracy.
Results: The mean age was 36.8±12.4 years; 94 patients (65.7%) were male, and the right knee was involved in 82 (57.3%). Arthroscopy demonstrated a meniscal tear in 105 patients (73.4%), whereas MRI demonstrated a tear in 104 (72.7%). Overall, MRI yielded 97 true-positive, 31 true-negative, 7 false-positive, and 8 false-negative results. Sensitivity was 92.4%, specificity 81.6%, PPV 93.3%, NPV 79.5%, and overall diagnostic accuracy 89.5%.
Conclusion: MRI demonstrated high diagnostic accuracy for meniscal injuries and is a useful non-invasive preoperative diagnostic modality. Arthroscopy remains the reference standard, particularly when persistent mechanical symptoms or therapeutic intervention require direct intra-articular assessment.
Downloads
References
1. Bhan K. Meniscal tears: current understanding, diagnosis,
and management. Cureus. 2020;12(6):e8590. doi:10.7759/
cureus.8590.
2. Evers BJ, van den Bosch MH, Blom AB, van der Kraan PM,
Koëter S, Thurlings RM. Post-traumatic knee osteoarthritis:
the role of inflammation and hemarthrosis on disease
progression. Front Med (Lausanne). 2022;9:973870.
doi:10.3389/fmed.2022.973870.
3. Sanjay N, Shanthappa AH, Kurahatti A, Kumaar A.
Comparison of clinical, magnetic resonance imaging and
arthroscopic findings in assessment of cartilage defects and
internal derangement of knee. Cureus. 2023;15(6):e40810.
doi:10.7759/cureus.40810.
4. Khalid D, Iqbal J, Mustafa K, Altaf R, Fatima R. Diagnostic
accuracy of magnetic resonance imaging in the detection of
meniscal injury in patients with knee trauma: keeping
arthroscopy as a gold standard. Cureus. 2024;16(10):e72343.
doi:10.7759/cureus.72343.
5. El-Hagrasy AMA, Theckayil AJ, Khan MA, Khan HN, Butt
AJ. Magnetic resonance imaging is an effective first line
noninvasive tool for meniscal tear detection: a retrospective
comparative analysis with knee arthroscopy. Arthrosc Sports
Med Rehabil. 2024;12(1):101065. doi:10.1016/j.asmr. 2024.
101065.
6. Bottomley J, Smith C, Brown T, Patel R, Wilson A, Jones M,
et al. Diagnostic accuracy of magnetic resonance imaging in
detecting meniscal tears compared with arthroscopy. Cureus.
2025;17(8):e87143. doi:10.7759/cureus.87143.
7. Wang W, Li Z, Peng H, Zhang J, Chen L, Liu Y, et al. Accuracy
of MRI diagnosis of meniscal tears of the knee: a systematic
review and meta-analysis. J Knee Surg. 2021;34(2):121-129.
doi:10.1055/s-0039-1695746.
8. Kim SH, Lee HJ, Jang YH, Kim JH, Park YB, Lee DH, et al.
Diagnostic accuracy of magnetic resonance imaging in
predicting lateral meniscus tear location. Diagnostics (Basel).
2021;11(2):336. doi:10.3390/diagnostics11020336.
9. Allende F, Dyrna F, Achtnich A, Herbst E, Forkel P, Imhoff
AB, et al. Meniscal ramp lesion classification systems: a
systematic review. Knee Surg Sports Traumatol Arthrosc.
2024;32(6):1443-1456. doi:10.1007/s00167-024-07888-5.
10. Noorelahi Y, Khan MA, Ahmed F, Abbas M, Iqbal Z, Rehman
S, et al. Comparative diagnostic accuracy of MRI and
ultrasound for meniscal tears using arthroscopy as reference
standard. Cureus. 2025;17(10):e94612. doi:10.7759/
cureus.94612.
11. Anwar W, Rahman N, Khan HA, Kamran A, Niaz Z, Khattak
N. Diagnostic accuracy of magnetic resonance imaging in
diagnosing meniscal injuries in relation to knee arthroscopy.
Khyber J Med Sci. 2022;15(2):68-71.
12. Sajid M, Uppal MSK, Bajwa ZU, Riaz T. Diagnostic accuracy
of magnetic resonance imaging for meniscal knee injuries
taking arthroscopy as the gold standard. Biol Clin Sci Res J.
2023;2023:325.
13. Alardi IM, Kadhim AS. The comparison of diagnostic accuracy
of MRI in patients suspected with meniscus tear contrasted
to findings of arthroscopy. Bahrain Med Bull. 2024;46(4):2533-
2536.
14. Rinonapoli G, Caraffa A, Bisaccia M, Meccariello L, Rollo
G, Ceccarini P, et al. Clinical reliability of six meniscal tests:
a diagnostic accuracy study. J Clin Med. 2025;14(12):4216.
doi:10.3390/jcm14124216.
15. Ahmadi O, Rezaei M, Farahani A, Rahimi S, Ghasemi M,
Karimi N, et al. The predictive value of point-of-care
ultrasonography and MRI in medial meniscus injury. BMC
Musculoskelet Disord. 2024;25(1):92. doi:10.1186/s12891-
024-07179-7.
16. de Paula RE, Camargo OPA, Camanho GL, Hernandez AJ,
Astur DC, Cohen M, et al. Update on meniscal injury treatment.
Rev Bras Ortop. 2025;60(5):e701-e714. doi:10.1055/s-0045-
1809721.
17. Walter SS, Fritz J, Yi PH, Calabrese E, Recht MP, Sodickson
DK, et al. Deep learning superresolution for simultaneous
multislice accelerated knee MRI. Radiology. 2025;314(2):
e241121. doi:10.1148/radiol.241121.
18. Giammanco PA, Patel DB, Brandon CJ, Stevens KJ, Subhas
N, Fritz J, et al. Diagnostic accuracy of artificial intelligence
for detection of meniscal tears on MRI: systematic review
and meta-analysis. Skeletal Radiol. 2025;54(10):1901-1914.
doi:10.1007/s00256-025-04625-7.
19. Ayesha S, Anam F, Hussain A, Zahra M, Hayat F. Diagnostic
Accuracy of Magnetic Resonance Imaging for the Assessment
of Meniscal Tears Using Arthroscopic Findings as the Gold
Standard. J Saidu Med Coll. 2026;16(1):173–180.
20. Nasa A, Ahmed MA, Sasnur PA. Role of MRI in evaluation
of knee joint injuries and its correlation with arthroscopic
findings. Int J Radiol Res. 2024;6(2):56-61. Available from:
https://radiologyjournal.in/assets/archives/2024/vol6issue2/
6020.pdf
Downloads
Published
Issue
Section
License

This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
Journal of Bahria University Medical & Dental College is an open access journal and is licensed under CC BY-NC 4.0. which permits unrestricted non commercial use, distribution and reproduction in any medium, provided the original work is properly cited. To view a copy of this license, visit https://creativecommons.org/licenses/by-nc/4.0