Physical Examination Of Arteriovenous Fistula: A Basic Approach In AV Fistula Stenosis Detection

Authors

  • Aisha Bibi
  • Sohail Sabir
  • Irfanul Haq

Keywords:

Arteriovenous fistula, Stenosis, Physical examination. MDCTA, Doppler ultrasound

Abstract

Objectives: To determine the accuracy and equivalence of physical examination, MDCTA and Doppler ultrasound in detection of arteriovenous fistula (AVF) stenosis.

Materials and Methods: We conducted a pilot study in hemodialysis department of PNS Shifa withprospective diagnostic cohort design on 15 patients, referred for evaluation of arteriovenous fistuladysfunction. Physical examination of arteriovenous fistula was done followed by Doppler ultrasound and MDCTangiography.The results of each patient was recorded and sealed. Data analyzed byCohen's Kappa, which determined the level of agreement between the diagnosis made by Physical examination, MDCTangiography and Doppler ultrasound .

Results: There was significant agreement in AVF stenosis detection made by physical examination and MDCTangiography (K: 0.865 for inflow stenosis and K: 0.602 for outflow stenosis).Whereas moderate level of agreement was observed between physical examination and Doppler ultrasound (K: 0.471 for inflow stenosis, K: 0.444 for outflow stenosis). Fair agreement existed between MDCTA and Doppler ultrasound in outflow stenosis detection.

Conclusion: Physical examination is accurate and equivalent in AVF stenosis detection when compared with MDCTangiography and superior in stenosis detection when compared with Doppler ultrasound in our hospital. Doppler Ultrasound is inferior to MDCTA in diagnosis of outflow stenosis

References

Salman L, Ladino M, Alex M, Dhamija R, Merrill D, Lenz O, et al. Accuracy of ultrasound in the detection of inflow stenosis of arteriovenous fistulae: results of a prospective study. Seminars in Dialysis-2010; 23(1):117-21

Ko SF, Huang CC, Ng SH. MDCT angiography for evaluation of the complete vascular tree of hemodialysis fistula. AJR 2005;185:1268-74

National Kidney Foundation: K-DOQI clinical practice guidelines for vascular access: Update 2000.Am J Kidney Dis 2001; 37(1):S137-S81

Heye S, Maleux G, Claes K, Kuypers D, Oyen R.:Stenosisdetection in nativehemodialysis fistulas with MDCT angiography. AJR 2009, 192:1079-84

Choi JR, Kim YS,Won YD ,Son YS ,Song WJ,Song HC ,et al. Accuracy of physical examination in the detection of arteriovenous fistula dysfunction. Korean J Nephrol 2006; 25:797-802

Beathard GA: Physical Examination of the dialysis vascular access.Semin Dial 2001;11:231-6

Beathard GA:Physical Examination: Theforgotten tool In:A Multidisciplinary Approach for Heamodialysis Access, editors: Gray R,Sands J, New York, Lippincott Williams &Wilkins,2002 pp11-118

Schwab SJ, Raymond JR, Saeed M, Newman GE, Dennis PA, Bollinger RR. Prevention of hemodialysis fistula thrombosis.Early detection of venous stenoses. Kidney Int 1989; 36: 707-11

Finlay DE, Longley DG, Foshager MC, Letourneau JG. Duplex and color Doppler sonography of hemodialysis arteriovenous fistulas and grafts . Radiographics1993;13:983–9

Collins DM, Lambert MB, Middleton JP, Proctor RK, Davidson CJ, Newman GEet al.Fistula dysfunction: Effect on rapid hemodialysis. Kidney Int1992;41:1292-6

D-Marchi S,Felleti E,Giacomello R,Stel G,Cecchin E,Sepiachi G et al. Risk factors for vasculardisease and arteriovenous fistula dysfunction in hemodialysis patients.J Am Soc Nephrol1996;7(8):1169-77

Coantrao L,Faria B, Pestana M. Physical examination of dysfunctional AV fistula by non inter ventionalists: A skill worth teaching.Nephrol Dial Transplant 2012;27(5):1993-6

Goldblum SE, Ulrich JA, Goldman RS, Reed WP, Avasthi S. Comparison of 4% chloro hexidine gluconate in a detergent base (Hibiclens) & povidine-iodine (Betadine) for skin preparation of hemodialysis patients and personnel. Am J Kidney Dis 1983;2: 548-52

Nicoletti G, Boghossian V, Borland R.Hygienic hand disinfection: A comparative study with chlorhexidine detergents and soap. J Hospital Infect 1990; 15:323-37

Larson EL, Morton HE. In: Alcohols: Disinfectant, Sterilization, and Preservation. Editors Melvern, PA, Lee and Sebiger, 4th edition. 1991 pp 191-203

Hartigan MF, Thomas-Hawkins C. Circulatory Access for Hemodialysis In: Lancaster LE ANNA Core Curriculum for Nephrology Nursing 3rd edition. Editors Pitman, NJ, Anthony J. Jannetti, 1995, pp 259-80

Hartigan MF. Vascular access and nephrology nursing practice: Existing views and rationales for change. AdvRen Replace Ther1994;1:155-62

Tonelli M, Jhangri GS, Hirsch DJ, Marryatt J, Mossop P, Wile C,et al.Best threshold for diagnosis of stenosis or thrombosis within six months of access flow measurement in arterio venoua fistula Nephrol1995;6(7):1109-14

Doelman C, Duijm LE, Liem YS, Froger CL, Tielbeek AV, Donkers-van Rossum AB et al.Stenosis detection in failing hemodialysis access fistulas and grafts: comparison of color Doppler ultrasonography, contrast-enhanced magnetic resonance angiography, and digital subtraction angiography.

Nephrol 1996; 7(9) 1258-63

Leypoldt JK. Diagnostic methods for vascular access: access flow measurements contributions to Nephrology 2002;137: 31-37

Besarab A, Sullivan K L, Ross R, Moritz M J. The utility of intra-access pressure monitoring in detecting and correcting venous outlet stenoses prior to thrombosis Kidney International,1995; 47(5):1364-73

Sullivan KL,Besarab A. Hemodynamic screening and early percutaneousintervention reduce hemodialysis access thrombosis and increase graft longevity, Journal ofVascular and Interventional Radiology 1997; 8(2):163-70

Besarab A, Frinak S,ShermanR A. Simplified measurement of intra-access pressure: Journal of the American Society of Nephrology 1998; 9(2): 284-9

Tessitore N, Bedogna V, Melilli E. In search of an optimal bedside screening program for arteriovenous fistula stenosis. Clinical Journal of American Society of Nephrology 2011;6( 4):819-26

Fowler PR, Steinberg AW, Wlodarczyk JH, Nanra RS, Hibberd AD. Use of the fistula assessment monitor to detect stenoses in access fistulae. Am J Kidney Dis 1991;17:303-6

Downloads

Published

2013-06-20

How to Cite

Bibi, A. ., Sabir, S. ., & Haq, I. . (2013). Physical Examination Of Arteriovenous Fistula: A Basic Approach In AV Fistula Stenosis Detection. Journal of Bahria University Medical and Dental College, 3(1), 16–19. Retrieved from https://jbumdc.bahria.edu.pk/index.php/ojs/article/view/48

Issue

Section

Original Articles

Most read articles by the same author(s)